True
Product Image

Dahua PFM922I-6UN-C UTP CAT6 - 305m Cable Solid CCA - PVC Bleu - Certifié classe ignifuge CE CPR Eca

19,000.00 DA 19,000.00 DA

Dahua PFM922I-6UN-C UTP CAT6 - 305m Cable Solid CCA - PVC Bleu - Certifié classe ignifuge CE CPR Eca

SKU:

N/A
| EAN: 6923172555069

  • category.name
  • category.name
  • category.name
Create a new review

Cable Type: UTP CAT6
Length (m): 305
Wire Material: CCA(Copper content 8%~12% ), HDPE, Polyester, PVC
Grande résistance aux flammes du PVC

2
  • Body-Color
  • Materials
  • Longueur
  • Cable Type
  • Certification Incendie

Demandez le prix

Chargement des offres
SKU:
DS-WSEWI-T2/4200
Share :


     
  • 7-day returns
  • Shipping: 2-3 Days

 

Conductor

Material

CCA(Copper content 22%–31%)

Diameter

0.57 mm ± 0.01 mm

American Wire Gauge

23AWG

Insulation

Material

HDPE

Min. Average Thickness

0.21 mm

Diameter

1.02 mm ± 0.06 mm

Color (4 Pairs)

Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Separator

Material

PE

Specification

Translucent 4.5 × 0.4 mm

Rip Cord

Material

Polyester

Specification

500D

Sheath

Material

PVC

Min. Average Thickness

0.5 mm

Diameter

6.5 mm ± 0.3 mm

Color

Orange

Electrical

Max. DC Resistance of a Single Conductor

11.5Ω/100 m

Min. Insulation Resistance

5000MΩ·km

Max. DC Resistance Unbalance

2% (pair intra), 4% (pairs inter)

Dielectric Strength

No breakdown with 1KV DC for 1 min

Transmission

Characteristic Impedance

100 ± 15Ω

Near End Cross Talk

≥39.30 dB/100 m@250 MHz

Max. Attenuation

34.8 dB/100 m@250 MHz

Return Loss

≥17.3 dB/100 m@250 MHz

Mechanical

Tensile Strength

Sheath≥13.5 MPa, insulation≥16 MPa

Elongation at Break

Sheath≥150%, insulation≥300%

Installation Bending Radius

>8 times of outer cable diameter

Conductor Elongation at Break

≥10%

Environmental

Shrinkage of Insulation

≤5%

Color Migration Resistance of Insulation

No migration

Sheath Tensile Strength and Elongation at Break after Aging

≥12.5 MPa, ≥100%

Low Temperature Bending Test

No cracking after the test

Heat Shock Test

No cracking after the test

Operation Temperature

–20°C to +60°C (–4°F to 140°F)

Installation Temperature

0°C to +50°C (32°F to 122°F)

Storage Temperature and Humidity

–10°C to +40°C (14°F to 104°F), <60% (RH)

Security

Vertical Fire Propagation Test

Comply with IEC 60332-1-2

Packaging

Length

305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)

Packaging Dimensions

390.0 mm x 390.0 mm x 247.0 mm (15.37"x15.37"x9.73") (L × W × H)

Packaging Method

305.0 m (1000.66 ft) a carton, one protection carton with 2 cartons inside

Net Weight

≥9.2 kg (20.28 lb)

Gross Weight

≥10.2 kg(22.49 lb)

Executive Standard

Executive Standard

Q/DXJ 067-2019

Certification

Certification

CPR Eca